Structural Adhesive Instrument
Structural Adhesive Instrument
Structural Adhesive Instrument
Structural Adhesive Instrument
+
  • Structural Adhesive Instrument
  • Structural Adhesive Instrument
  • Structural Adhesive Instrument
  • Structural Adhesive Instrument

Structural Adhesive Instrument

The structural sealant compatibility test chamber is used to evaluate the compatibility of structural assembly system components—such as weatherstripping, spacers, gaskets, and fixing blocks—with sealants, as well as to determine the test methods and criteria for assessing compatibility. It is suitable for material selection in architectural curtain wall systems. Changes in adhesion and color after testing are critical indicators for evaluating material compatibility; experience has shown that components that lose adhesion or discolor during testing will exhibit similar behavior in actual service.

WhatsApp phone:

Keywords:

  • Product Description
  • Product Overview

    The structural sealant compatibility test chamber is used to evaluate the compatibility of structural assembly system components—such as weatherstripping, spacers, gaskets, and fixing blocks—with sealants, as well as to determine the test methods and criteria for assessing such compatibility. It is suitable for material selection in architectural curtain wall systems. Changes in adhesion and color after testing are critical indicators for evaluating material compatibility; experience has shown that components that lose adhesion or discolor during testing will exhibit similar behavior in actual service.

    This test chamber complies with the requirements specified in GB 16776-2005, “Silicone Structural Sealant for Building Applications.”

    Main Technical Parameters

    Ultraviolet power 60W × 4 units
    Temperature control accuracy 40.0℃~50.0℃, ±0.5℃
    Temperature measurement range 0~65℃
    Irradiation set duration 0~999.9 hours
    Heater power 1000W
    External dimensions 1280×516×800mm
    Power supply 220V AC ±10%, 1.5 kVA
    Net weight of the equipment 90kg

Reasons to Choose Us

Multiple specifications to choose from

Source factory

Ships promptly

Thoughtful service

Supports customization

Selected Raw Materials

Factory Advantages

Deep expertise, comprehensive product range

Deep expertise, comprehensive product range

Over 10 years of dedicated R&D and manufacturing of testing instruments for highway, construction, geotechnical, asphalt, cement, and other engineering applications.
Comprehensive category coverage: from raw material testing to construction quality control, a one-stop solution.
Compliant with international standards such as ISO and GB, meeting the regulatory requirements of overseas projects.

Customized Solutions

Reliable quality and excellent value for money.

We strictly adhere to the ISO 9001 quality management system, select core components from internationally renowned brands, and conduct full inspection before shipment.
In-house manufacturing + a large-scale supply chain deliver strong price competitiveness, with no markups from intermediaries.
Stable and durable, with a low failure rate, reducing operational and maintenance costs for overseas customers.

Efficient delivery, global service

Efficient delivery, global service

In-stock inventory plus flexible manufacturing ensures 7–15 day rapid delivery, with support for customized rush orders.
Cangzhou’s Lin’gang District boasts a strategic location, with convenient sea and air transportation and globally traceable logistics.
Multilingual team with 24-hour technical support, offering installation and commissioning, training, a three‑year warranty, and ongoing follow-up services.

Operating with integrity and backed by extensive experience.

Operating with integrity and backed by extensive experience.

13 years of industry expertise, serving over 30 countries and regions worldwide.
The principle of “integrity in business, mutual benefit.”
Deep understanding of international engineering standards and procurement processes, with efficient communication and seamless collaboration.

Frequently Asked Questions

Is the universal materials testing machine experiencing loading stalling or abnormal zeroing of load data?


1. Loading lag: Clean the lead screw and guide rails, apply lubricant, and remove debris from the transmission components. 2. Zeroing anomaly: Restart the equipment system, calibrate the load and displacement zero points, and check for poor electrical contact in the sensor wiring. 3. Overloading is strictly prohibited; before testing, verify that the grips are securely tightened to prevent eccentric loading of the specimen.

How often should in‑instrument verification be performed? Which instruments are required to undergo it?


High‑precision, high‑frequency‑use, and drift‑prone equipment (such as balances, penetration testers, water permeability testers, and sensor‑type devices) shall undergo intermediate verification every three months; routine equipment shall be verified every six months. Equipment that is within the verification/calibration interval, has been repaired following a malfunction, or has been relocated must undergo additional intermediate verification, with complete verification records maintained.

Is the repeatability of pendulum-type pavement friction coefficient measurements poor?


Key points for resolution: Prior to testing, thoroughly clean the pavement at each measurement point, ensuring there is no standing water, dust, or debris; calibrate the instrument’s level and zero point to ensure a standardized pendulum‑drop trajectory; strictly control the pendulum’s sliding distance; avoid conditions such as strong winds, wet pavement, or abrupt temperature changes; and calculate the average of multiple measurements taken at the same point.

How should one handle cases where the pavement infiltration meter data exceeds allowable error limits, exhibits leakage, or shows abnormal readings?


1. Sealing leaks: Inspect the base seal for aging or damage and replace it promptly; before testing, firmly press down on the base to expel any residual air inside. 2. Data deviation > ±2%: Calibrate the level sensor, clean any fouling from the graduated cylinder, and check for damage to the scale markings. 3. Compliance with new regulations: For seepage rates ≤ 300 mL/min, existing equipment may continue to be used; for rates > 300 mL/min, the accuracy of older equipment fails to meet standards, and such equipment must not be used.

Can the old Marshall compaction apparatus and stability tester still be used?


According to the 2025 revised asphalt testing procedures, after adjusting the indenter configuration on the Marshall stability test apparatus, existing instruments currently in use may continue to be operated normally without mandatory replacement; only periodic calibration to maintain accuracy and ensure equipment integrity is required.

What are the causes of uneven compaction and layered cracking in molded specimens during compaction testing?


Main causes: non‑vertical drop of the compaction hammer, rail jamming, excessive deviation in hammer weight, uneven layer thickness during loading, insufficient number of blows, or overload. Solutions: regularly lubricate the guide rails; verify and correct the vertical alignment of the hammer; strictly follow the procedure for layered material placement and step‑by‑step compaction; ensure that hammer weight and drop height comply with standards; and prevent over‑thick layers.

Get more product information for free

*Note: Please provide accurate information and keep your communication channels open. We will contact you as soon as possible.

Submit Now

Related products

The LS-500B fully automatic high-strength bolt testing instrument can measure and test the axial force, torque, and torque coefficient of large hexagonal‑head high‑strength bolt assemblies (M16, M20, M22, M24, M27, M30), displaying and printing the results. When the axial force reaches the value specified by the standard, the instrument emits an audible beep and records the test data; simultaneously, it automatically calculates and displays the torque coefficient based on the measured axial force and torque. After completing a test series, the instrument automatically computes the average axial force, average torque, average torque coefficient, standard deviation, and coefficient of variation for N specimens. Users can enter the test number, as well as the bolt’s grade, class, and specification. The control system cyclically updates and stores the data, allowing it to be retrieved and printed at any time.
View Details View More
The DQ-4 rock cutting machine utilizes a diamond‑tipped circular blade to cut and sample various non‑metallic solid materials. It is suitable for cutting and sampling rocks, ores, construction concrete, and refractory bricks, and serves as essential equipment for sample preparation in the petroleum, geological, coal, construction, and transportation industries.
View Details View More
This apparatus is used to determine the proportional limit compressive strength of wood in the transverse direction, including both the overall and local proportional limit compressive strengths. It is suitable for measuring the transverse proportional limit compressive strength of sound small‑size specimens. The device complies with the requirements of GB/T 1927.12‑2021, “Test Methods for Physical and Mechanical Properties of Sound Small‑Size Wood Specimens — Part 12: Determination of Transverse Compressive Strength.”
View Details View More
The boiling-water bath method is used to determine the water absorption of ceramic tiles, daily-use ceramics, architectural and sanitary ceramics, and electrical porcelain. It can also be applied to measure the water absorption of bricks, tiles, cement products, and similar materials.
View Details View More
< 123 >

Request a quote now

We will contact you within one business day. Please check your email.

Submit